Treatment of Bicondylar Tibial Plateau Fractures by single lateral locked Plate
Ahmed Hasan El.Bana Ibrahim;
Abstract
Introduction: Bicondylar tibial plateau fractures need surgical treatment to
achieve good clinical results. The locking plate combines the technical advantages of
an angular stable plate with those of the modern biological plating technique.
Hypothesis: Bicondylar Tibial Plateau Fractures can be effectively managed
using a single lateral locking plate.
Materials and methods: Between May 2012 and November 2013, 20 patients
with a mean age of 38 years (Range from 24-57 years) with bicondylar tibial plateau
fractures with or without metaphyseal extension. Patients were diagnosed clinically,
checked with standard X-rays, CT was done for all cases. Patients were treated by
single lateral anatomically contoured locked plate through LISS or Polyaxial locking
plate systems with or without additional screws from medial side. Radiological
evaluation and functional assessment was done according to the Rasmussen Knee
score. Patients were followed-up for an average of 12 months.
achieve good clinical results. The locking plate combines the technical advantages of
an angular stable plate with those of the modern biological plating technique.
Hypothesis: Bicondylar Tibial Plateau Fractures can be effectively managed
using a single lateral locking plate.
Materials and methods: Between May 2012 and November 2013, 20 patients
with a mean age of 38 years (Range from 24-57 years) with bicondylar tibial plateau
fractures with or without metaphyseal extension. Patients were diagnosed clinically,
checked with standard X-rays, CT was done for all cases. Patients were treated by
single lateral anatomically contoured locked plate through LISS or Polyaxial locking
plate systems with or without additional screws from medial side. Radiological
evaluation and functional assessment was done according to the Rasmussen Knee
score. Patients were followed-up for an average of 12 months.
Other data