Effect of Retention Sil Versus Ball and Socket Attachment on the Supporting Structures of Implant retained Mandibular Overdentures

Ahmed Abd Al-Kader Ali Saif;

Abstract


Introduction: Introduction of dental implant retained overdentures in the field of dentistry improves retention and stability of dentures and improve function when compared to conventional dentures, therefore implant retained overdenture is considered the first treatment option for mandibular edentulous patients which mainly complain from instability of their mandibular dentures. Aims: This study radiographically assesses the effect of retention sil versus ball and socket attachment on the supporting structures of mandibular implant retained overdentures. Materials and Methods: Fourteen completely edentulous patients were selected from the outpatient clinic Faculty of Dentistry, Ain Shams University according to the following criteria:
Results: All the selected patients were rehabilitated by mucosa supported maxillary complete denture and implant retained mandibular overdenture. Patients participating in this study were randomly divided into two equal groups according to the type of attachment:
Group I: Patients were received lower implant retained overdenture relined with " Retention Sil " soft liner.
Group II: Patients were received lower implant retained overdenture with ball and socket attachment.
Conclusion: Patient rehabilitation with implant retained overdenture using retention sil had a better effect on bone resorption compared to the effect of ball and socket.
Recommendation: Based on the results of this study, it was recommended to carry out the same study but regarding to the difference in the retentive value between ―Retention Sil‖ material and ball and socket attachment.
Keywords: Radiographically, Sil Versus Ball,Socket Attachment, Mandibular Overdentures


Other data

Title Effect of Retention Sil Versus Ball and Socket Attachment on the Supporting Structures of Implant retained Mandibular Overdentures
Other Titles المقارنةبين البطانة المرنة للأطقم من فئة "ريتينشنسيل" مقابل الكرةوالمقبس على الأنسجة الداعمة للغرسات السنية في حالات الاطقم المحمولة علي غرسات سنية
Authors Ahmed Abd Al-Kader Ali Saif
Issue Date 2016

Attached Files

File SizeFormat
G13444.pdf776.5 kBAdobe PDFView/Open
Recommend this item

Similar Items from Core Recommender Database

Google ScholarTM

Check



Items in Ain Shams Scholar are protected by copyright, with all rights reserved, unless otherwise indicated.