A Comparative Study of TwoDifferent Designs of Kennedy Class IIIModification 1 in Removable PartialDentures: Finite Element Analysis

Heba Ahmed Mohamed Ahmed Saleh;

Abstract


In this vitro study two lower dentulous models were used to
represent Kennedy class III modification 1.The abutment teeth were the
canines and the second molars bilaterally. Removable partial dentures
were constructed on these models with different types


Other data

Title A Comparative Study of TwoDifferent Designs of Kennedy Class IIIModification 1 in Removable PartialDentures: Finite Element Analysis
Other Titles مقارنة بين تصميمين مختلفين للاطقم الجزئية في حالاتكينيدى القسم الثالث تعديل رقم ١: دراسة بطريقة العناصرالمحدده
Authors Heba Ahmed Mohamed Ahmed Saleh
Keywords A Comparative Study of Two Different Designs of Kennedy Class III Modification 1 in Removable Partial Dentures: Finite Element Analysis
Issue Date 2011
Description 
In this vitro study two lower dentulous models were used to
represent Kennedy class III modification 1.The abutment teeth were the
canines and the second molars bilaterally. Removable partial dentures
were constructed on these models with different types

Attached Files

File SizeFormat
Binder1.pdf163.62 kBAdobe PDFView/Open