Effect Of The Capsule-Bending Ring On Posterior Capsular Opacification

Hoda Taha El-Shiwy;

Abstract


PCO is still a major complication of modern cataract surgery. Recently, it was concluded that the creation of a discontinuous sharp bend in the capsule by the sharp edged PMMA capsule-bending ring (CBR), leads to inhibition of LECs migration and decrease in incidence of PCO. In this study. the results showed that no opacification occurred in any of the eyes with the CBR implanted before the implantation of a single piece PMMA IOL (after phacoemulsification and bimanual irrigation/ aspiration through 2 corneal stab incisions) while 6 eyes (20%)of those without the CBR implantation and who had cataract extr ction by the same technique and implantation of the same type of IOL had opacified posterior capsules. It was concluded that the reduction in the rate of PCO was due to the inhibition of LECs migration at the sharp bend in the capsule created by the CBR.


Other data

Title Effect Of The Capsule-Bending Ring On Posterior Capsular Opacification
Other Titles تاثير الحلقة المزروعة داخل المحفظة علي عتامة المحفظة الخلفية للعدسة
Authors Hoda Taha El-Shiwy
Keywords Posterior capsule opacification - Capsule bending ring- Capsule tension ring - Posterior chamber IOLs- Elshnig's pearls- Soemmering ring.
Issue Date 2001

Attached Files

File SizeFormat
Hoda Taha El-Shiwy.pdf2.26 MBAdobe PDFView/Open
Recommend this item

Similar Items from Core Recommender Database

Google ScholarTM

Check