Recent and past earthquake damages have proven that buildings can undergo significant structural damage under
intense ground shakes. One of the possible factors that may lead to structural damage is the seismic pounding
phenomenon, where adjacent buildings with insufficient gap distance may collide with each other leading to
excessive shear forces and moments. As pounding may cause fatal outcomes, evaluation of code requirements for
the gap distance between adjacent buildings is addressed in this thesis. A parametric study on the inelastic response
of flat slab buildings under seismic action is carried out. In addition, the study evaluates the requirements of
Egyptian Code of Practice regarding separation distance between adjacent mid-rise flat slab buildings. In this study,
typical RC flat slab buildings, with three heights, represents residential buildings designed in accordance with the
Egyptian Standards are analyzed using nonlinear time history analysis. Ten different earthquake records with 6
different peak ground accelerations varying from 0.15g to 0.7g are considered herein in order to simulate
constructing the same buildings in different locations with different earthquake intensity. In this regard, fragility
curves, which illustrate the relation between the peak ground acceleration and the probability of certain damage
occurrence, are established for the concerned buildings considering different damage states. Then, more than 350
nonlinear pounding scenarios between adjacent buildings are studied and compared with Egyptian Code of Practice
requirements, clarifying the need to adjust the Egyptian Code to prevent all pounding probabilities, especially for
smaller earthquake intensities less than 0.3g


Other data

Title EVALUATION OF CODE REQUIRED SEPARATION DISTANCE BETWEEN ADJACENT R.C FLAT SLAB MID-RISE BUILDINGS
Other Titles تقييم لمتطلبات الكود للمسافة الفاصلة بين المبانى الخرسانية المتجاورة متوسطة الارتفاع ذات البلاطات المسطحه
Authors Hosam Eldin Mohamed Gamal Mahmoud
Issue Date 2018

Attached Files

File SizeFormat
V3658.pdf371.68 kBAdobe PDFView/Open
Recommend this item

Similar Items from Core Recommender Database

Google ScholarTM

Check

views 8 in Shams Scholar
downloads 16 in Shams Scholar


Items in Ain Shams Scholar are protected by copyright, with all rights reserved, unless otherwise indicated.