The role of multidetector CT virtual hysterosalpingography in the evaluation of female infertility

Abdelrahman, Ahmed S.; S. IBRAHIM, Ahmed; Hetta, Waleed M.; Elbohoty, Ahmed E.; Guirguis, Mounir S.;

Abstract


Purpose To assess the role of 64-row multidetector computed tomography virtual hysterosalpingography (MDCT VHSG) in the evaluation of the female reproductive tract in infertile patients and compare it with conventional X-ray hysterosalpingography (HSG). Methods and material The studied group included 25 patients with infertility. All patients were evaluated with 64-row MDCT VHSG and X-ray HSG. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of both examinations for uterine pathology, fallopian tube pathology and per lesion pathology were calculated. The duration for both examinations, patient discomfort and patient effective dose were documented. Results The mean duration for MDCT VHSG and X-ray HSG was 6.5 ± 1.9 and 26.9 ± 2.9 min respectively, MDCT VHSG has a significantly less median patient discomfort and mean patient effective dose. Sensitivity, specificity, PPV and NPV for uterine pathology were 100%, 100%, 100% and 100% respectively for MDCT VHSG and 90%, 93.3%, 90% and 93.3% respectively for X-ray HSG, the inter-method agreement for uterine pathology was k = 0.83. Sensitivity, specificity, PPV and NPV for the detection of fallopian tube pathology were 100%, 93%, 91 and 100% respectively for MDCT VHSG and 100%, 86%, 85% and 100% respectively for X-ray HSG and k = 0.76. Sensitivity, specificity, PPV and NPV for per patient pathology were 100%, 91%, 93% and 100% respectively for MDCT VHSG and 87%, 80%, 87% and 80% respectively for X-ray HSG and k = 0.75. Conclusion MDCT VHSG could be an excellent new alternative diagnostic procedure in the infertility assessment workup. © 2014 Production and hosting by Elsevier B.V.


Other data

Title The role of multidetector CT virtual hysterosalpingography in the evaluation of female infertility
Authors Abdelrahman, Ahmed S. ; S. IBRAHIM, Ahmed ; Hetta, Waleed M. ; Elbohoty, Ahmed E. ; Guirguis, Mounir S. 
Issue Date 2014
Publisher ELSEVIER SCIENCE BV
Journal The Egyptian Journal of Radiology and Nuclear Medicine 
DOI 3
959
https://api.elsevier.com/content/abstract/scopus_id/84905918588
45
10.1016/j.ejrnm.2014.04.005
Scopus ID 2-s2.0-84905918588
Web of science ID WOS:000216522300042

Recommend this item

Similar Items from Core Recommender Database

Google ScholarTM

Check

Citations 5 in scopus
views 8 in Shams Scholar


Items in Ain Shams Scholar are protected by copyright, with all rights reserved, unless otherwise indicated.