Factors affecting upon the calibration factor of radon dosimeter: Theoretical and experimental study

Ashry, Ashry Hasan; Abouleila, Mohammed; Abdalla, A.M.;

Abstract


The calibration factor of radon dosimeter (CR-39 track detector) for radon and its daughters has been determined theoretically and experimentally at different environmental conditions, i.e., humidity and temperature. The effect of humidity was examined practically and correlated with theoretical studies. From the detailed studies, it was observed that the theoretical value of calibration factor was larger than the experimental one at low-relative humidity condition. The effect of temperature on the calibration factor of CR-39 track detector was examined theoretically. It was found from the theoretical studies that the calibration factor increases with increasing the temperature. © 2010 American Scientific Publishers.


Other data

Title Factors affecting upon the calibration factor of radon dosimeter: Theoretical and experimental study
Authors Ashry, Ashry Hasan ; Abouleila, Mohammed ; Abdalla, A.M.
Issue Date 2010
Journal Advanced Science Letters 
Volume 3
Issue 4
Start page 518
End page 522
DOI 10.1166/asl.2010.1148

Recommend this item

Similar Items from Core Recommender Database

Google ScholarTM

Check



Items in Ain Shams Scholar are protected by copyright, with all rights reserved, unless otherwise indicated.