Corrosion protection of Mg-1%Zn and Mg-6%Zn orthopedic implant alloys in simulated body fluid

Marwa Mohammed Mohammed Mohammed Esmail;

Abstract


The present study investigates the use of four bathes I , II, III and IV in electrodeposition on two different alloys Mg - 1% Zn and Mg - 6% Zn.
The experimental results obtained and their interpretation is included in chapter III.
Chapter III deals with electro plating for the four bathes containing Ca(NO3)2 as the calcium ion source, di-ammonium di- hydrogen phosphate NH4H2PO4 as the phosphate ion source, sodium nitrate NaNO3 to increase conductivity, hydrogen peroxide (H2O2) to erase at pot 1.4V.

Coat Bath I Bath II Bath III Bath IV
Composition
CaNO3 9.90 g/l 9.90 g/l 11.00 g/l 11.00 g/l
NH4H2PO4 2.87 g/l 4.00 g/l 2.87 g/l 4.00 g/l
NaNO3 1.27 g/l 1.27 g/l 1.27 g/l 1.27 g/l
Na3PO4 2.00 g/l 2.00 g/l 2.00 g/l 2.00 g/l
H2O2 20.00 ml/l 20.00 ml/l 20.00 ml/l 20.00 ml/l


In part one the electrodeposition was studied of the four bathes on Mg-1%Zn alloy. The surface morphology of the coat have


Other data

Title Corrosion protection of Mg-1%Zn and Mg-6%Zn orthopedic implant alloys in simulated body fluid
Other Titles حماية سبائك Mg-1%Zn, Mg-6%Zn لتستخدم كشرائح للعظام من التاكل فى محلول يحاكى محلول الجسم
Authors Marwa Mohammed Mohammed Mohammed Esmail
Issue Date 2019

Attached Files

File SizeFormat
cc1555.pdf802.84 kBAdobe PDFView/Open
Recommend this item

Similar Items from Core Recommender Database

Google ScholarTM

Check

views 3 in Shams Scholar