DETERMINATION OF FLUORIDE RELEASE FROM FLUORIDE-RELEASING ELASTOMERIC LIGATURE TIES AND ITS IMPACT ON MICROBIAL GROWTH
KHALED SAMIR ABOULAZM;
Abstract
The first part of the study was designed to evaluate the rate of fluoride release from orthodontic fluoride releasing elastomeric ligature ties; it compared the fluoride release of fluoride releasing and non
fluoride releasing elastomeric ligature ties both in vitro and in vivo.
_..,....,,_
I
. ,,..
A total of 660 fluoride-releasing gray elastomeric ligatures and 420 non fluoride-releasing gray elastomeric ligatures were used in this study. The 24-hours released fluoride in TISAB was calculated after various periods of evaluation for both in vitro and in vivo samples, these samples were maintained in an incubator at 3_7° C for the 24 hours of evaluation.
The fluoride content of the test solutions was determined by means of the potentiometer analytic method. A fluoride-ion selective electrode and a reference electrode coupled to an analyzer were used.
for the in vitro part of the study, a total of 540 fluoride-releasing
' . '
elastomeric ligature ties and 300 nonfluoride-releasing elastomeric ligature ties were divided in groups of 20 each. The fluoride release was evaluated after being stored in two different rrtedia (artificial saliva and distilled water) at various intervals of: 24 hours, one week, two weeks, four weeks of storage.
fluoride releasing elastomeric ligature ties both in vitro and in vivo.
_..,....,,_
I
. ,,..
A total of 660 fluoride-releasing gray elastomeric ligatures and 420 non fluoride-releasing gray elastomeric ligatures were used in this study. The 24-hours released fluoride in TISAB was calculated after various periods of evaluation for both in vitro and in vivo samples, these samples were maintained in an incubator at 3_7° C for the 24 hours of evaluation.
The fluoride content of the test solutions was determined by means of the potentiometer analytic method. A fluoride-ion selective electrode and a reference electrode coupled to an analyzer were used.
for the in vitro part of the study, a total of 540 fluoride-releasing
' . '
elastomeric ligature ties and 300 nonfluoride-releasing elastomeric ligature ties were divided in groups of 20 each. The fluoride release was evaluated after being stored in two different rrtedia (artificial saliva and distilled water) at various intervals of: 24 hours, one week, two weeks, four weeks of storage.
Other data
| Title | DETERMINATION OF FLUORIDE RELEASE FROM FLUORIDE-RELEASING ELASTOMERIC LIGATURE TIES AND ITS IMPACT ON MICROBIAL GROWTH | Other Titles | تحديد الفلورين المنبثق من حلقات الربط المطاطية المفلورة وتأثيرها على نمو البكتريا | Authors | KHALED SAMIR ABOULAZM | Issue Date | 2004 |
Attached Files
| File | Size | Format | |
|---|---|---|---|
| B14646.pdf | 1.01 MB | Adobe PDF | View/Open |
Similar Items from Core Recommender Database
Items in Ain Shams Scholar are protected by copyright, with all rights reserved, unless otherwise indicated.