EPR dosimetric properties of 2-methylalanine pellet for radiation processing application

Soliman, YS; Laila I. Ali; Moustafa H.; Soad M.Tadros;

Abstract


The dosimetric characteristics of γ-radiation induced free radicals in 2-methylalanine (2MA) pellet dosimeter are investigated using electron paramagnetic resonance (EPR) in the high-dose range of 1-100. kGy. The EPR spectrum of γ-irradiated 2MA exhibits an isotropic EPR signal with seven lines. The dosimeter response is humidity independent in the range of 33-76% relative humidity. The manufactured dosimeter is typically adipose tissue equivalent in the energy level of 0.1-15. MeV. The overall uncertainty (2. σ) of the dosimeter is less than 6.9%. © 2014 Elsevier Ltd.


Other data

Title EPR dosimetric properties of 2-methylalanine pellet for radiation processing application
Authors Soliman, YS; Laila I. Ali ; Moustafa H. ; Soad M.Tadros 
Keywords 2-Methylalanine;Radiation dosimeter;EPR spectrometer;ELECTRON-SPIN-RESONANCE;L-ALANINE;CRYSTAL;ENDOR
Issue Date Sep-2014
Publisher PERGAMON-ELSEVIER SCIENCE LTD
Journal Radiation Physics and Chemistry 
Volume 102
Start page 11
End page 15
ISSN 0969-806X
DOI 10.1016/j.radphyschem.2014.04.021
Scopus ID 2-s2.0-84899850244