Distribution of angle lambda and pupil offset as measured by combined Placido Scheimpflug Topography

Gharieb, Hesham Mohamed; Shalaby, Hisham; Othman, Ihab Saad;

Abstract


Background: Angle lambda is the angle between the pupillary axis and the line of sight. It is important for accurate centration during anterior segment surgery. The purpose of this study is to identify the distribution of angle lambda and pupil center offset as measured by a combined placido disc Scheimpflug topography system.

Methods: A prospective non-randomized study was performed on 2178 eyes in Eye World Hospital, Giza, Egypt. Sirius device (CSO, Costruzione Strumenti Oftalmici, Florence, Italy, version 3.2.1.60) was used to measure average keratometry (K), anterior chamber depth (ACD), central corneal thickness (CCT), horizontal visible iris diameter (HVID), pupil radius (PR), pupil center intercept x-component (PCI-x), and pupil center intercept y-component (PCI-y). Axial length (AL) was measured by immersion A-scan Eyecube Ultrasonography device (Ellex, Adelaide, South Australia, Australia). Angle lambda was calculated by a trigonometrical equation. Pearson correlation was used to analyze the correlation between angle lambda and age and refraction.

Results: Average angle lambda in all eyes was 3.32° ± 1.99. Mean angle lambda was significantly smallest in myopia and largest in hyperopia. Age correlation to angle lambda was insignificant. Average PCI-x and PCI-y in all eyes was - 0.047 mm and + 0.091 mm, respectively.

Conclusions: Angle λ is significantly larger in hyperopia than myopia, and the effect of age is insignificant. Pupil center offset was horizontally greater in hyperopia than in myopia. We therefore encourage the preoperative assessment of angle λ to avoid decentered ablation, especially when treating hyperopia.


Other data

Title Distribution of angle lambda and pupil offset as measured by combined Placido Scheimpflug Topography
Authors Gharieb, Hesham Mohamed; Shalaby, Hisham ; Othman, Ihab Saad
Keywords Angle kappa; Angle lambda; Placido Scheimpflug topography; Pupil offset; Sirius
Issue Date 28-Jul-2022
Publisher SPRINGER
Journal International ophthalmology 
ISSN 1573-2630
DOI 10.1007/s10792-022-02394-3
PubMed ID 35900714
Web of science ID WOS:000832447300001

Recommend this item

Similar Items from Core Recommender Database

Google ScholarTM

Check

Citations 1 in scopus


Items in Ain Shams Scholar are protected by copyright, with all rights reserved, unless otherwise indicated.