Detection of induction motors rotor/stator faults using electrical signatures analysis

Shehata, Somaya A.M.; El-Goharey, Hamdy S.; Mostafa Ibrahim Mohamed Marei; Ibrahim, Ahmed K.;

Abstract


In this work induction motor faults detection using electrical signature analysis techniques are introduced, and the advantages and disadvantages of these techniques are explained. Stator phase current signature, stator current locus diagram, stator current vector signature, partial power signature, and total power signature are selected for the simulation study applied for 4Kw squirrel cage induction motor. Simulation results are shown to explain how these signatures can be used to detect rotor/stator faults. And finally the performance of each technique based on the sensitivity to fault severity, the effect of motor loading, and cost required for the practical implementation is discussed.


Other data

Title Detection of induction motors rotor/stator faults using electrical signatures analysis
Authors Shehata, Somaya A.M.; El-Goharey, Hamdy S.; Mostafa Ibrahim Mohamed Marei ; Ibrahim, Ahmed K.
Keywords Induction motor;Motor electrical signature analysis;Rotor fault detection;Stator fault detection
Issue Date 1-Mar-2013
Journal Renewable Energy and Power Quality Journal 
ISSN 2172038X
2172038X
DOI 10.24084/repqj11.318
Scopus ID 2-s2.0-85039415190

Recommend this item

Similar Items from Core Recommender Database

Google ScholarTM

Check

Citations 12 in scopus


Items in Ain Shams Scholar are protected by copyright, with all rights reserved, unless otherwise indicated.