Solid-state ion-selective electrodes for the first potentiometric determination of the anti-COVID 19 drug Remdesivir in human plasma; A comparative study

Morsy, Noha Fathy Elazab; Ahmed, Neven;

Abstract


Establishing sensitive and targeted analytical methodologies for drug identification in biological fluids as well as screening of treatments that can counteract the most severe COVID-19 infection-related side effects are of utmost importance. Here, first attempts have been made for determination of the anti-COVID drug Remdesivir (RDS) in human plasma using four potentiometric sensors. Calixarene-8 (CX8) was used as an ionophore applied to the first electrode (Sensor I). The second had a layer of dispersed graphene nanocomposite coating (Sensor II). (Sensor III) was fabricated using nanoparticles of polyaniline (PANI) as ion-to-electron transducer. A reverse-phase polymerization using polyvinylpyrrolidone (PVP) was employed to create a graphene-polyaniline (G/PANI) nanocomposite electrode (Sensor IV). Surface morphology was confirmed by Scanning Electron Microscope (SEM). UV absorption spectra and Fourier Transform Ion Spectrophotometry (FTIR) also supported their structural characterization. The impact of graphene and polyaniline integration on the functionality and durability of the manufactured sensors was examined using the water layer test and signal drift. In the ranges of concentration of 10-7 to 10-2 mol/L and 10-7 to 10-3, sensors II & IV exhibited linear responses; respectively while sensors I & III displayed linearity within 10-6 to 10-2 mol/L. The target drug was easily detectable using LOD down to 100 nmol/L. The developed sensors satisfactorily offered sensitive, stable, selective and accurate estimate of Remdesivir (RDS) in its pharmaceutical formulation as well as spiked human plasma with recoveries ranging from 91.02 to 95.76 % with average standard deviations less than 1.85. The suggested procedure was approved in accordance with ICH recommendations.


Other data

Title Solid-state ion-selective electrodes for the first potentiometric determination of the anti-COVID 19 drug Remdesivir in human plasma; A comparative study
Authors Morsy, Noha Fathy Elazab ; Ahmed, Neven
Keywords G/PANI nanocomposite;Graphene;Ion selective electrode;Plasma;Polyaniline nanoparticles;Remdesivir
Issue Date Jul-2023
Publisher Elsevier
Journal Microchemical journal : devoted to the application of microtechniques in all branches of science 
Volume 190
ISSN 0026-265X
DOI 10.1016/j.microc.2023.108658
PubMed ID 36970552
Scopus ID 2-s2.0-85150806905