Effect of important parameters on efficiency of Electrochemical Chloride Extraction

Abdelrahman Osama Elbany;

Abstract


Seven RC slabs were considered in the experimental program in order to investigate the effect of important parameters on the efficiency of ECE. These parameters are:
1) Spacing between reinforcing steel bars (steel bars act as a cathode).
2) Type of cathode (internal and external cathode were considered).
3) Thickness of RC slab (which control the distance between external anode and external cathode).
4) Number of reinforcing steel meshes inside the slab.
5) Location measured from the external anode.
Of course there are other important parameters affect the efficiency of ECE (such as current intensity, duration of ECE, type of anode, concrete strength,…etc.), these parameters were kept constant during the experimental investigation.