High flux versus Hemodiafiltration in removal of indoxyl sulphate

Amira Mohamed Mahmoud Abd El Ghani;

Abstract


The aim of this study is to compare removal of indoxyl sulphate toxin during single session between low flux, high flux hemodialysis and hemodiafiltration..
This cross sectional study was taking place in Ain Shams university hospital. The study was done on 60 hemodialysis patients divided into 3 groups based on dialysis modality:
Group 1: (20) patients received hemodialysis session using low flux filter.
Group 2: (20 patients received hemodialysis session using high flux filter.
Group 3: (20) patients received hemodiafiltration session.
This study included 66.67 % males (n=40) and 33.33% females (n=20), the mean age was 43.95 years in group 1, 48.35 years in group 2 and 45.10 years in group 3 with no significant difference in age and sex between groups.
73.33% of patients were HCV negative (n=44), 21.67% of patients were HCV positive (n=13) and 5% of patients received HCV treatment (n=3).
In our study the mean indoxyl sulphate level pre dialysis was 21.80 ± 8.89 pg\ml in low flux group, 22.20 ±


Other data

Title High flux versus Hemodiafiltration in removal of indoxyl sulphate
Other Titles الاستصفاء الدموي الترشيحي مقابل الاستصفاء الدموى باستخدام فلاتر عاليه التدفق في ازاله سم اندوكسيل الكبريتات
Authors Amira Mohamed Mahmoud Abd El Ghani
Issue Date 2020

Attached Files

File SizeFormat
BB7917.pdf1.84 MBAdobe PDFView/Open
Recommend this item

Similar Items from Core Recommender Database

Google ScholarTM

Check

views 1 in Shams Scholar