Non Invasive Cardiac Output and Haemodynamic Monitoring in Patients with Sepsis Receiving Crystalloid or Colloid

Khaled Abdel -Baqy Abdel- Rahman;

Abstract


he study was carried out on 40 patients with septic shock to evaluate the effect of the type of volume loading (crystalloid or colloid) on the cardiac output and other haemodynamics of those patients. The included patients were diagnosed as septic patien
The study was carried out on 40 patients with septic shock to evaluate the effect of the type of volume loading (crystalloid or colloid) on the cardiac output and other haemodynamics of those patients. The included patients were diagnosed


Other data

Title Non Invasive Cardiac Output and Haemodynamic Monitoring in Patients with Sepsis Receiving Crystalloid or Colloid
Other Titles متابعة غير مقتمحه لصادر القلب وديناميكية الدوره الدمويه فى مرض الخمج بعد استخدام المحاليل شبه البللوريه او المحاليل شبهه الغرويه
Authors Khaled Abdel -Baqy Abdel- Rahman
Issue Date 2004