(The Effect of Different Crown – Implant Ratios on Peri-Implant Crestal Bone Levels (A Clinical and CBCT Evaluation
Ghada Moustafa Mohamed Kamel;
Abstract
Therefore, this study was conducted to compare the effect of different crown-implant ratios on peri-implant crestal bone levels.
The study was conducted on ten patients in the same age range and medically free. Mandibular posterior areas were selected as they play an important role in the patient’s comfort.
Each patient received two implants of the same width and same design, they differed only in the length of the implant. Each implant supported a single fixed restoration.
The following clinical parameters : gingival index score, plaque index score, bleeding index score and probing depth were conducted at 1, 3, 6 months after prosthetic loading.
Clinical results showed no statistically significant (p-value ≥ 0.05) change in median gingival index scores, plaque index score, bleeding index score and probing depths measurements between short and long implants.
The method we used to measure the marginal bone changes in this study was the Cone Beam Computed Tomography (CBCT) after 6 months of prosthetic loading
The study was conducted on ten patients in the same age range and medically free. Mandibular posterior areas were selected as they play an important role in the patient’s comfort.
Each patient received two implants of the same width and same design, they differed only in the length of the implant. Each implant supported a single fixed restoration.
The following clinical parameters : gingival index score, plaque index score, bleeding index score and probing depth were conducted at 1, 3, 6 months after prosthetic loading.
Clinical results showed no statistically significant (p-value ≥ 0.05) change in median gingival index scores, plaque index score, bleeding index score and probing depths measurements between short and long implants.
The method we used to measure the marginal bone changes in this study was the Cone Beam Computed Tomography (CBCT) after 6 months of prosthetic loading
Other data
| Title | (The Effect of Different Crown – Implant Ratios on Peri-Implant Crestal Bone Levels (A Clinical and CBCT Evaluation | Other Titles | تأثير النسب المختلفة للتاج وطول غرسة الأسنان على مستوى العظم الحافى (تقييم اكلينيكى و باستخدام الأشعه المقطعية المخروطية) | Authors | Ghada Moustafa Mohamed Kamel | Issue Date | 2019 |
Recommend this item
Similar Items from Core Recommender Database
Items in Ain Shams Scholar are protected by copyright, with all rights reserved, unless otherwise indicated.