This study was a cross over study conducted to compare between the accuracy of two different impression techniques of dental implants.
This study included ten completely edentulous patients. Patients were selected from the Outpatient Clinic, Removable Prosthodontics Department, Faculty of Dentistry, Ain-Shams University. Complete denture was constructed for each patient.
A CBCT was made for each patient to place two interforaminal implants. Two different techniques were made for each patient. In the first technique, open top impression was made and master cast was poured and scanned and an STL file was obtained. In the second technique, digital impression was made by scanning the two implants intraorally using intraoral scanner. Then, STL file was exported and superimposition of these STL files was done.
The results of this study revealed statistically insignificant difference between the two impression techniques.
This study was a cross over study conducted to compare between the accuracy of two different impression techniques of dental implants.
This study included ten completely edentulous patients. Patients were selected from the Outpatient Clinic, Removable Prosthodontics Department, Faculty of Dentistry, Ain-Shams University. Complete denture was constructed for each patient.
A CBCT was made for each patient to place two interforaminal implants. Two different techniques were made for each patient. In the first technique, open top impression was made and master cast was poured and scanned and an STL file was obtained. In the second technique, digital impression was made by scanning the two implants intraorally using intraoral scanner. Then, STL file was exported and superimposition of these STL files was done.
The results of this study revealed statistically insignificant difference between the two impression techniques.
Other data
| Title | Evaluating accuracy of digital scanography impression technique versus passive fit impression technique | Other Titles | تقييم دقة المسح الرقمي كطريقة مقاس للغرسات السنية مقابل طريقة مقاس الصواني المفتوحة | Authors | Doreya Amr Abo El Makarem | Issue Date | 2022 |
Attached Files
| File | Size | Format | |
|---|---|---|---|
| BB13707.pdf | 439.59 kB | Adobe PDF | View/Open |
Similar Items from Core Recommender Database
Items in Ain Shams Scholar are protected by copyright, with all rights reserved, unless otherwise indicated.