Effect of using teeth positioning guides on the accuracy of CAD/CAM complete dentures: an in-vitro study
Muhammad Amr Nabil Sadek Ali;
Abstract
This study was conducted to evaluate the accuracy of teeth positions when positioned manually, and with a teeth positioning guide.
An educational maxillary edentulous model made of dental stone were used for this study. Upon each model two complete dentures were fabricated. Thus, two groups were defined according to the method of positioning of the teeth.
Group I: Six printed upper complete dentures were fabricated, and the teeth were manually positioned in the recesses of the denture bases.
Group II: Six printed upper complete dentures were fabricated, and the teeth were positioned in the recesses of the denture bases using a teeth positioning guide.
The accuracy of teeth positions in both groups were evaluated and compared using the Geomagic control x software.
Data was collected and statistically analyzed. The results of accuracy of the teeth it was found that the least deviation was found in group I. There was a statistically significant difference between the two groups.
An educational maxillary edentulous model made of dental stone were used for this study. Upon each model two complete dentures were fabricated. Thus, two groups were defined according to the method of positioning of the teeth.
Group I: Six printed upper complete dentures were fabricated, and the teeth were manually positioned in the recesses of the denture bases.
Group II: Six printed upper complete dentures were fabricated, and the teeth were positioned in the recesses of the denture bases using a teeth positioning guide.
The accuracy of teeth positions in both groups were evaluated and compared using the Geomagic control x software.
Data was collected and statistically analyzed. The results of accuracy of the teeth it was found that the least deviation was found in group I. There was a statistically significant difference between the two groups.
Other data
| Title | Effect of using teeth positioning guides on the accuracy of CAD/CAM complete dentures: an in-vitro study | Other Titles | تأثير استخدام دليل تحديد موقع الأسنان على دقة الأطقم الكاملة المصنعة بتقنية الكاد/كام: دراسة مختبرية | Authors | Muhammad Amr Nabil Sadek Ali | Issue Date | 2022 |
Attached Files
| File | Size | Format | |
|---|---|---|---|
| BB12286.pdf | 432.15 kB | Adobe PDF | View/Open |
Similar Items from Core Recommender Database
Items in Ain Shams Scholar are protected by copyright, with all rights reserved, unless otherwise indicated.