Mechanical Bruising to Strawberry Caused by Vibrational Equipment.

Mayhoub, M. A.; Elsahhar, Essam; A. A. Abdel-Hafez; M. Z. El-Attar;

Abstract


Packaged strawberry of two cultivars grown in Egypt were submitted to vibrational equipment. During test, the accelerations at three different positions of the column of crates were measured. Vibrational energy during transportation fruits was 1200 J/kg resulting bruise 7, 7.3% for the two cultivars Festival and Fortuna, resp. Bruise due to vibration stress occurred in 25 and 48.2% for Festival and Fortuna cultivars, respectively. The degree of maturity of 80-85% to less damage, where the proportion of the damage with the highest vibratory energy (2100 J/kg), while 25%. Exposed strawberries placed in the middle crate into the biggest damage where the percentage of damage to 50% at the end of the storage period.


Other data

Title Mechanical Bruising to Strawberry Caused by Vibrational Equipment.
Authors Mayhoub, M. A.; Elsahhar, Essam ; A. A. Abdel-Hafez; M. Z. El-Attar
Issue Date 2016
Journal Misr Society of Agric. Eng.‎ 
Volume 3
Issue 33
DOI 10.21608/MJAE.2016.97747

Recommend this item

Similar Items from Core Recommender Database

Google ScholarTM

Check



Items in Ain Shams Scholar are protected by copyright, with all rights reserved, unless otherwise indicated.