Evaluation of landline local loops in Egypt

Islam Amin Mohamed Ibrahim Ellabban;

Abstract


The landline fixed telephone copper network of Telecom Egypt (TE) company is evaluated. A sample of that network is tested using different available tests. The imperfections of the network is discussed and analyzed to specify the reasons for those imperfections. A new methodology to measure the transmission line parameters and determine the Resistance Fault Location (RFL) using “Three Voltmeter Method” is also introduced. The parameters measurement error percentage is acceptable (< 10%) for resistance, capacitance, characteristic impedance, attenuation constant and phase constant. The inductance and conductance suffer from small accuracy values. The RFL measurement has an error percentage of 6.54% for short cable length and small error value. The methodology used the “Three Voltmeter Method” in addition to Data Acquisition System (DAS).


Other data

Title Evaluation of landline local loops in Egypt
Other Titles تقييم خطوط التليفون الأرضى فى مصر
Authors Islam Amin Mohamed Ibrahim Ellabban
Issue Date 2015

Attached Files

File SizeFormat
G10477.pdf558.99 kBAdobe PDFView/Open
Recommend this item

Similar Items from Core Recommender Database

Google ScholarTM

Check

views 4 in Shams Scholar


Items in Ain Shams Scholar are protected by copyright, with all rights reserved, unless otherwise indicated.