Rapid and Low-Cost Detection of Human Corona Virus Using MEMS ATR-FTIR Spectroscopy
Sabry, Yasser M.; Ghoname, Amr O.; kelany, mohamed; Mohamed, Moustafa; Mostafa, Ahmed; Khalifa, Amgad; Okda, Sherif; Erfan, Mazen; Anwar, Momen; Sakr, Omar S.; Othman, Ahmed M.; Saadany, Bassam; Khalil, Diaa;
Abstract
The conventional methods used for the diagnostics of viral infection are either expensive and time-consuming or not accurate enough and dependent on consumable reagents. In the presence of pandemics, a fast and reagent-free solution is needed for mass screening. Recently, the diagnosis of viral infections using infrared spectroscopy has been reported as a fast and low-cost method. In this work a fast and low-cost solution for corona viral detection using infrared spectroscopy based on a compact micro-electro-mechanical systems (MEMS) device and artificial intelligence (AI) suitable for mass deployment is presented. Among the different variants of the corona virus that can infect people, 229E is used in this study due to its low pathogeny. The MEMS ATR-FTIR device employs a 6 reflections ZnSe crystal interface working in the spectral range of 2200-7000 cm-1. The virus was propagated and maintained in a medium for long enough time then cell supernatant was collected and centrifuged. The supernatant was then transferred and titrated using plaque titration assay. Positive virus samples were prepared with a concentration of 105 PFU/mL. Positive and negative control samples were applied on the crystal surface, dried using a heating lamp and the spectrum was captured. Principal component analysis and logistic regression were used as simple AI techniques. A sensitivity of about 90 % and a specificity of about 80 % were obtained demonstrating the potential detection of the virus based on the MEMS FTIR device.
Other data
| Title | Rapid and Low-Cost Detection of Human Corona Virus Using MEMS ATR-FTIR Spectroscopy | Authors | Sabry, Yasser M.; Ghoname, Amr O.; kelany, mohamed ; Mohamed, Moustafa; Mostafa, Ahmed; Khalifa, Amgad; Okda, Sherif; Erfan, Mazen ; Anwar, Momen; Sakr, Omar S.; Othman, Ahmed M.; Saadany, Bassam; Khalil, Diaa | Keywords | ATR;Clinical testing;COVID-19 Virus;MEMS FTIR;Optical spectroscopy;Photonics;Point-of-care testing;Reagent-free analysis | Issue Date | 1-Jan-2023 | Conference | Progress in Biomedical Optics and Imaging Proceedings of SPIE | ISBN | [9781510658219] | ISSN | 16057422 | DOI | 10.1117/12.2644313 | Scopus ID | 2-s2.0-85159781469 |
Attached Files
| File | Description | Size | Format | Existing users please Login |
|---|---|---|---|---|
| SPIE PW2023_Rapid and low-cost detection of human corona virus using MEMS ATR-FTIR spectroscopy_1235803.pdf | 373.42 kB | Adobe PDF | Request a copy |
Similar Items from Core Recommender Database
Items in Ain Shams Scholar are protected by copyright, with all rights reserved, unless otherwise indicated.